The DTE–450/2000 output parameters specification

Output Terminal U1: ~ 450/5 – Adjustable AC Voltage

Adjustment range of the output voltage, V 0,2..50 2,0..250 4,0..450
Rated output current, A 5 5 3
Maximum output current, А 8 8 5
Rated output power, kW 1,5
Maximum output power, kW 2,5
Adjustment step of the output voltage when using single-phase voltage regulator (laboratory autotransformer), V, at most 0,1 0,25 0,45
Protection: FU1 – fuse-link, A 10

Output terminal U1: ± 450/5 – Adjustable rectified voltage

Adjustment range of the output voltage, V 0,2..50 2,0..250 4,0..450
Rated output current, A 5 5 3
Maximum output current, А 8 8 5
Rated output power, kW 1,5
Maximum output power, kW 2,5
Adjustment step of the output voltage when using single-phase voltage regulator (laboratory autotransformer), V, at most 0,1 0,25 0,45
Protection: FU1 – fuse-link, A 10

Output Terminal U2: Adjustable Alternative Current and Voltage

Adjustment range of the output voltage, V 0,05..10
Adjustment range of the output current, A/td> 0…20 0…200
Rated output current when using single-phase voltage regulator (laboratory autotransformer), A 20 200
Maximum output current when using single-phase voltage regulator (laboratory autotransformer), A 22 220
Protection: Circuit breaker device C25, Im setting of current measurer 22 220

Output Terminal U3: Adjustable Alternative Current and Voltage

Adjustment range of the output voltage, V 0,03..3,3
Adjustment range of the output current, A/td> 0…2000
Maximum output current when using built-in TR, A
Максимальный выходной ток при работе с встроенным ТР, А 2000
Protection: Circuit breaker device C25, Im setting of current measurer 2200

You can see the 3D model of the device at this link

Gallery