High Voltage Diode Device DTE-30/80 purpose

Testing device DTE-30/80 is designed for testing of power cables insulation and solid dielectrics by rectified electric voltage, as well as for solid dielectrics testing by sinusoidal electric voltage of 50 Hz frequency. The device is designed to operate under a canopy or indoors
at operating temperatures from -10 °C to + 40 °C,
up to 80% relative air humidity at +20°C and
atmospheric pressure 84.0 – 106.7 kPa (630 – 800 mm. Hg. v.).

Technical specifications

Power supply single-phase AC voltage230V ± 11
Device parameters on rectified voltage in prolonged mode (up to 5 minutes) and power supply nominal voltage:
– Maximum operating voltage (peak value)30 kV
– Maximum operating current30 mA
Device parameters at AC voltage in prolonged mode (up to 5 minutes) and power supply nominal voltage:
– Maximum operating voltage (rms)21 kV
– Maximum operating current (rms)80 mA
Reduced measurement error of the output voltage and current, at most3%
Power consumption, at most3 kW
Weight, at most
Control unit weight13 kg
High voltage unit weight44 kg

Operating Conditions

The device is designed for operation in environments excluding exposure to aggressive external factors (rain, fog, dust, direct sunlight, and other adverse conditions) and is intended for use both as part of mobile electrical laboratories and stationary installations under the following conditions:

ParameterValue
Operating temperature, °С−10…+40
Storage temperature, °С−10…+45
Relative humidity at +20 °C, %≤ 85
Atmospheric pressure, kPa84…106.7 (630…800 mmHg)

You can see the 3D model of the device at this link

Gallery